Thursday, 10 November 2016

RPFT Exam Question No 41

Question No 41:


What are examples of certifications
RPFT (Respiratory Pulmonary Function Technologist), NPS (Neonatal/Pediatric respiratory care Specialist), ACCS (adult critical care specialty)

Sunday, 16 October 2016

Second-year Respiratory Therapy Students Complete PALS Certification

The sophomores in the respiratory therapy program large community of sand and Technical College (BSCTC) completed the PALS (Pediatric Life Support) Tuesday 20 September workout.

The group has also completed the ACLS (Advanced Cardiac Life Support) in August Both teams were provided by Gina Lester, RRT-NPS, RPFT, education coordinator in the Valley pull the Regional Healthcare Appalachians. Lester is a graduate of the respiratory therapy program BSCTC 1998.

"This is an important step for our students to complete our program," said Melissa Skeens, program coordinator BSCTC respiratory therapy. "I am proud of this achievement, and I am equally proud that one of our graduates provides training".

Dr. Devin Stephenson, president of BSCTC, congratulated the students on their achievement.

"This is the next step in an exciting chapter in their lives," he said. "I am looking forward to returning graduate in May."

the second year of the program students are: Brittany Taylor, Kierstin Woods, Kristen Hall, Justin Robinson, Kendra Kidd and Indya Williamson.

Thursday, 30 June 2016

RPFT Exam Question No 40

Question No 40:

A pulmonary function technologist is reviewing an asthma action plan. The patient takes a low-dose inhaled corticosteroid and a long-acting beta2-agonist twice daily. The patient's personal best peak flow is 600 L/min. Which of the following instructions should be given to the patient when the peak flow drops to 500 L/min?

A. Add montelukast (Singular).
B. Continue the current regimen.
C. Go to the emergency department.
D. Double the steroid dose.

Answer: A

Thursday, 23 June 2016

RPFT Exam Question No 39

Question No 39:

An isothermal lung analog has the following specifications:

5-L glass bottle
2000 g of steel wool
Density of steel wool 5 g/cm3

Volume of connectors and bulb 100 mi-Repeated FRC measurements in the plethysmograph
result in a volume of 5.5 L. Which of the following should a pulmonary function technologist
do?

A.
Remove 500 g ofsteel wool from the lung analog
B.
Take the plethysmograph out of service
C.
Recalculate the BTPS correction
D.
Begin a biologic control program

Answer: D

Thursday, 16 June 2016

RPFT Exam Question No 38

Question No 38:

Which of the following problems may be identified by using an isothermal lung analog to perform quality control on a body plethysmograph?

1. 1.Improperly calibrated mouth pressure transducer
2. 2.Obstructed or perforated pneumotachometer
3. 3.Increase in mechanical resistance
4. 4.Malfunctioning box pressure transducer

A.
3 and 4 only
B.
2 and 3 only
C.
1 and 4 only
D.
1 and 2 only

Answer: C

Friday, 10 June 2016

RPFT Exam Question No 37

Question No 37:

While performing duplicate blood gas analyses, a pulmonary function technologist notes that the second instrument gives consistently higher values forPaCO2and PaO2. Which of the following is the most probable cause of higher readings from the second instrument?

A.
The sample chamber temperature is greater than 37° C
B.
An excessive delay occurred between running the two samples
C.
The PO2and PCO2electrodemembranes have protein build-up
D.
The sample chamber has a bacterial contaminate

Answer: A

Thursday, 31 March 2016

RPFT Exam Question No 36

Question No 36:

Which of the following is the most reliable method to estimate the effectiveness of standard procedures to minimize the risk of cross-contamination during spirometry testing in a pulmonary function laboratory?

A.
Count the number of disposable mouthpieces used for 1 week.
B.
Observe the handwashing behavior of each technologist.
C.
Ask patients tested about laboratory hygiene.
D.
Ask technologists if they wash their hands before each test

Answer: B